Pole self-resetting differential 2- 25A 30mA...
Pole self-resetting differential 2- 25A 30mA Class A-SI - Toscano

Pole self-resetting differential 2- 25A 30mA Class A-SI - Toscano

€121.84 Tax included

€102.39 tax excl.

Single-phase RCD with automatic reclosing 25A 30mA (0.03A) Class A-SI, 2 poles . Self-resetting RCD for alternating and pulsating current, Type A-SI, designed to guarantee continuous and efficient protection. It has 3 reset attempts and an alarm contact to indicate the end of the automatic reset attempts. The device only reconnects when the fault that caused the tripping has disappeared.


Reference: VDA2P2530REC





Representative image for illustrative purposes, the item supplied will correspond to the specifications indicated.

No queries yet, leave the first!
 

Self-resetting Circuit breaker (RCD) for alternating and pulsating current, Type A-SI, 2-pole, 25A 30mA. Designed to guarantee safety and continuity of supply, it offers an intelligent solution to prevent interruptions in electrical installations due to insulation/shunt problems in homes, industries, and the service sector. It also protects people and equipment from ground faults.


Residual current device (RCD) with the option to choose between an automatic reset system, just like a standard RCD where reconnection must be performed manually. The automatic reconnection mode allows up to three reset attempts at 10-second/60-second/300-second intervals. The device only reconnects when the fault that caused the trip has disappeared. It has a system that emits a warning to indicate the end of automatic reset attempts. If the closure fails after 15 minutes, the auxiliary alarm signal is activated. It has a hole for passing a seal or padlock to block access to the RCD and any manual reconnection attempt.

After a trip due to an RCD trip, after a time delay, it evaluates whether the anomaly that caused the trip is temporary or permanent, performing a measurement to check for the existence of a leakage current. If the problem was a transient peak, the VDA-REC will attempt to reset the circuit after a few seconds. The device attempts to perform up to three measurements to check the leakage current; after this number of measurements is exceeded, the device is blocked and cannot automatically reconnect. Leakage current monitoring is performed by measuring the downstream resistance once the RCD has tripped.

This type of element is specifically designed for any electrical installation where full service continuity is required in the event of unforeseen situations that could trigger the RCD due to causes unrelated to electrical insulation. This is key in second homes, businesses that must remain operational, or facilities where a minor outage could cause disruption. Furthermore, by reducing the time without power, the deprogramming of electronic equipment, the interruption of critical systems, the loss of refrigerated food, or simply the inconvenience of being without power for an extended period of time are avoided.


Some of the sectors where this type of equipment provides the greatest value are:

  • Residential use: The VDA-REC not only protects the safety of people and the condition of the facility, but also guarantees rapid service recovery if the anomaly is temporary.
  • Commercial and light industrial: Small businesses, offices, or workshops where a power outage can affect productivity benefit significantly.
  • Sectors with critical systems: In critical environments, such as facilities with medical equipment, security systems or computer servers, etc.




Technical characteristics:

  • Manufacturer: Toscano
  • Reference: VDA2P2530REC
  • Number of poles: Pole + Neutral
  • Class: A
  • Nominal voltage: 240Vac
  • Nominal frequency: 50/60 Hz
  • Nominal intensity (In): 25A
  • Nominal sensitivity (IΔn): 30mA (0.03A)
  • Breaking capacity (Icn): 10kA
  • Cutting time:
  • Insulation voltage (Ui): 500V
  • Rated impulse withstand voltage (Uimp): 4000V
  • Trigger indicator: Yes
  • Rearmament attempts: 3
  • Reset times: 10s / 60s / 300s
  • Alarm connector: If the closure fails within 15 minutes
  • Protection level: IP20
  • Ambient temperature: -5ºC to +40ºC
  • Maximum cable section: 25mm²
  • Mounting: DIN rail (35mm) fixed by claws
  • Connection: Top or Bottom Entry
  • Directives: 2014-35-EU (LVD), 2014-30-EU ( EMC ); 2011-65-EU (RoHS)


Dimensions (mm):





Professional use material, install in compliance with the regulations in force at the place of installation.

Questions

Be the first to ask a question about this product!

Question about the product

* Required fields
(read)

Responsible: ADAJUSA (CONSTRUCCIONES PBR, S.L.), purpose: Respond to requests for information, legitimacy: consent of the interested party, recipients: data will not be communicated to third parties, rights: Access, rectify and delete data, as well as other rights, as explained in the additional information. (read)