MCB circuit breaker 2 poles 80A 10kA - Hyundai Electric
MCB circuit breaker 2 poles 80A 10kA - Hyundai Electric

MCB circuit breaker 2 poles 80A 10kA - Hyundai Electric

€25.49 Tax included

€21.42 tax excl.

2-pole 80A C-curve MCB circuit breaker for short-circuit and overload protection in industrial and tertiary applications. Hyundai brand. With a rated breaking capacity of 10,000A (10kA) according to IEC/EN60898, active pole protection with individual status indication for each pole.

Reference: HGD100S-2P080C .

2-pole magnetic thermal electrical diagram


Representative image for illustrative purposes, the item supplied will correspond to the specifications indicated.

No queries yet, leave the first!
 

2-pole 80A 10kA "C" curve MCB circuit breaker for short-circuit and overload protection in single-phase or two-phase installations. With a rated breaking capacity of 10kA, active pole protection with status indication. Manufactured from flame-resistant thermoplastic material and in compliance with IEC/EN60947-2.

The main features of this range of products include:

  • Precise actuation of the trigger lever.
  • Easy removal from DIN rail.
  • 13 plates in the extinguishing chamber for efficient arc cooling.
  • Free-tripping mechanism. The switch trips even if it is forced into the ON position.
  • Visual status indication, Red-ON, Green-OFF.
  • Supports the mounting of a large number of accessories.

Main features of the magnetothermal switch:

  • Manufacturer/Supplier: Hyundai Electric .
  • Manufacturer reference: HGD100S-2P080C .
  • Nominal intensity of the magnetothermic (In): 80A.
  • Number of poles: 2 (2x80A).
  • Step: 3 modules.
  • Breaking capacity (Icn): 10000A (10kA) (Ics=75% icn).
  • Maximum operating voltage (Ue): 240/415Vac, 50/60Hz.
  • Characteristic curve: C.
  • Rated insulation voltage (Ui): 690Vac.
  • Nominal impulse withstand voltage (Uimp): 4 KV.
  • Dielectric strength: 2.5kV.
  • Protection: IP20.
  • Endurance: ≥10000/20000.
  • Operating temperature: -5ºC...+55ºC.
  • Humidity: 95% RH.
  • Energy limitation class: Class 3.
  • Regulations: CE; IEC60947-2 industrial application (type H), IEC60898-1 residential application.
  • Terminal type: Screw clamping jaw.
  • Maximum terminal capacity: 50mm².
  • Maximum tightening torque: 2.5 Nm.
  • Weight: 0.300 Kg.
  • Dimensions (mm): 81x74.5x79.5.
  • Mounting position: Vertical/Horizontal.
  • Housing material : Flame-retardant molded thermoplastic.
  • Supports mounting of auxiliary elements: YES.

Dimensions of HGD 125 magnetothermics
Professional use material, install in compliance with current regulations at the place of installation.

Questions

Be the first to ask a question about this product!

Question about the product

* Required fields
(read)

Responsible: ADAJUSA (CONSTRUCCIONES PBR, S.L.), purpose: Respond to requests for information, legitimacy: consent of the interested party, recipients: data will not be communicated to third parties, rights: Access, rectify and delete data, as well as other rights, as explained in the additional information. (read)