Protective relay surge coil emission - Hypro
Protective relay surge coil emission - Hypro
Protective relay surge coil emission - Hypro
Protective relay surge coil emission - Hypro
Protective relay surge coil emission - Hypro
Protective relay surge coil emission - Hypro

Protective relay permanent and transient surges on emission coil - HY

€227.64 Tax included

€191.29 tax excl.

Device for protection against transient and permanent surges in three-phase lines, which acts on emission coil associated with IGA or molded box.

Associated with a cutting element, it allows protection against permanent surges due to increases in network voltage and transient surges (lightning strikes or switches) in three-phase installations.

Reference: ST-4PB.

No queries yet, leave the first!
 

Combined protection device against transient and permanent surges to associate an emission coil (trigger) with a cutting device (IGA) or molded box, in three-phase systems.

The operation of this protection module is to produce a disconnect signal to the general cut-off switch, general automatic switch (IGA) or molded box, when it is subjected to a higher voltage than it had to receive, in a continuous way and to ground the transient surges caused by lightning drop or the switching of electrical distribution lines.

This device, very compact and simple installation, provides very high protection, both against transient or permanent surges, as well as line, by incorporating an IGA (MCB circuit breaker) with a cutting power of 10kA. It has a visual indicator of cutting status.

The supply does not include the MCB circuit breaker, nor the emission coil, only the surge protector.

Technical features:

  • Manufacturer/Supplier: Hyundai Electric
  • Ref: ST-4PB.
  • Nominal voltage UN 240Vac. (N/l1, N/L2, N/L3).
  • Power consumption: 0.6VA.
  • Maximum terminal cable section: 16 mm2 (IGA) 6 mm2 (module).
  • Alarm contact: 5A / 30VDC, 5A / 250Vac.
  • Protection: IP20.
  • Mounting: Rail DIN 35.
  • DIN module number: 4 (TRIO) 9 (COMBI).
  • Regulations: EN 60898 / EN 50550 / IEC 61643-11.
  • Trigger tension: 265VAC +/- 2%. (N/L1, N/L2, N/L3).
  • Permanent Overvoltage Response Time:
    • 265Vac: Approximately 7s.
    • 300Vac: Approximately 3s.
    • 350Vac: Approximately 0.5s.
    • 400Vac: Approximately 0.15s.
  • Reset time: 10s.
  • Maximum current: 20kA (8/20).
  • Overvoltage response time: according to UNE-EN 50550 overvoltage.
  • Regulations: IEC61643-11 / EN 61643-11
  • CE marking.

Notes on assembly.

It is mandatory to connect the neutral to the N terminal and the ground conductor.

Instalación sobretension transitorio y permanente trifasico

The MCB circuit breaker or the emission coil (shot) is included in the supply, you have to order them separately.